Linear Instruments

Quick Search

Home

About Us

Our Products

Contact Us

Enquiry

Turbidity

Share: FacebookTwitterStumble
The USEPA and Standard Methods recommend a particular wavelength in the visible range of the spectrum and the European system requiring an infrared light source (ISO 7027). In order to satisfy these different requirements, HANNA has developed products that meet both standards


Hi 88713 Turbidity Meter

Hi 88713 Turbidity Meter

  • Graphic display, backlit LCD
  • Two, three, four or five point calibration
  • GLP features
  • Log up to 200 records
  • Contextual help and tutorial mode
  • USB PC connectivity
     

The HI 88713 turbidity bench meter meets and exceeds the requirements of the
ISO 7027 standard.

HI 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the LED, limiting the need for frequent calibration.

Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.

A two, three, four or five-point calibration can be performed using the supplied standards. Calibration points can be modified when user prepared standards are used.

The HI 88713 turbidity bench meter has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions.

The HI 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic LCD. Comprehensive contextual help is available at a simple key press. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process.

Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.

Send Enquiry

HI 98713 Portable Turbidity Meter

HI 98713 Portable Turbidity Meter

  • Two, three or four point calibration
  • USB and RS 232 PC connectivity
  • Log up to 200 records
  • GLP Features
  • User friendly, backlit LCD display with guidance codes
  • Battery % on startup
  • Continuous current time on display


 

The HI 98713 meets and exceeds the requirements of the ISO 7027 for water quality and provides a reliable and accurate readings on low turbidity values. An effective algorithm calculates and converts the detectors output in FNU. Depending on the needed accuracy, normal, continuous, or signal averaging can be selected.

The optical system—The Infrared Method (ISO 7027), consists of a infrared LED and two detectors (scattered and transmitted light), that assures long term stability and minimizes stray light and color interferences. HI 98713 also compensates for variations in intensity of the LED, minimizing the need for frequent calibration.

This instrument incorporates complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked at the touch of a button.

With it’s logging function, up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).

Exclusive Fast Tracker™

For advanced field applications, the HI 98713 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.

Send Enquiry

Hi 83414 Turbidity Meter

Hi 83414 Turbidity Meter

  • HI 83414 features four measuring ranges: ratio, non ratio, free chlorine, total chlorine
  • Meets USEPA requirements
  • Exclusive chlorine CAL CHECK™ calibration validation
  • GLP Features
  • Two, three, four or five point turbidity calibration
  • USB PC connectivity
  • Backlit LCD
  • On-screen tutorial and help modes
  • Log and recall up to 200 measurements
  • Contextual help and tutorial mode
  • Auto-off

 

HI 83414 is a highly accurate dual parameter instrument that reflects HANNA’s years of experience. The HI 83414 successfully combines turbidity and colorimetric measurements to test the most important parameters of drinking water: turbidity and free/total chlorine. The meter is specially designed for water quality measurements, providing reliable and accurate readings on low turbidity and chlorine values. The HI 83414 meets and exceeds the requirements of USEPA and Standard Methods both for turbidity and colorimetric measurements.

With the powerful CAL CHECK™ function, reliable performance can be validated at any moment by using the exclusive HANNA ready-made, NIST traceable standards. A one-point calibration can be performed using the same CAL CHECK™ standard.

This instrument features an optical system to guarantee accurate results, assure long term stability and minimize stray light and color interferences. They also compensate for variations in intensity of the lamp for less frequent calibration.

The 525 nm interference filter of the colorimeter assures accurate and repeatable results. Repeatability of the measurements are ensured with 25 mm round cuvettes made from special optical glass.

Turbidity measurements can be made in the 0.00 to 4000 NTU (Nephelometric Turbidity Units) range when ratiometric measurements are used and in the 0.00 to 40.0 NTU range when non ratio method is used. The HI?83414 has an EPA compliance reading mode which rounds the reading to meet EPA reporting requirements. Alternative EBC and Nephelos measuring units are available. Depending on the measured sample and needed accuracy, normal measurement, continuous measurement or signal averaging measurement can be selected.

A two, three, four or five-point calibration can be performed by using the supplied (<0.1, 15, 100, 750 and 2000 NTU) standards. If user prepared standards are used, the calibration points can be modified. Free or total chlorine measurements can be made in the 0.00 to
5.00 mg/L (ppm) range.

HI 83414 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked.

This meter also incorporates a user-friendly interface with an easy to understand, graphic LCD. All messages are in plain text making them easy to read. Comprehensive contextual help is available at the press of a button. All messages and help screens are available in several languages. Confirmation and error acoustic signals help the user during instrument operation. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process.

The logging function offers complete measurement information. Up to 200 measurements can be stored in the internal memory and consulted at any time. For further storage or analysis options, data can be downloaded to a PC using the USB port.

Send Enquiry

Hi 83749 Turbidity Meter

Hi 83749 Turbidity Meter


  • GLP Features
  • Fast Tracker™ with iButton™ tags    
  • Continuous measurement mode; Verifies the settling rate of suspended matter.
  • Signal Average (AVG) mode; Accumulates multiple readings giving a final average value.
  • Backlit LCD
  • USB
     

Wines with low phenol contents, such as rosé, light reds and whites should be checked for protein stability before bottling. HANNA is offers a quick test to verify the risk of future protein haze formation. If protein instability is detected, a subsequent test can help define the right amount of bentonite to be added for improving protein stability. It is important not to overdose bentonite to avoid stripping wine flavor, body, and significant loss of color, especially in young red wines. Moreover, adding only the necessary amount of bentonite to obtain the desired protein stability also saves costs.

The HI 83749 measures turbidity of samples from 0.00 to 1200 NTU (Nephelometric Turbidity Units) and is USEPA compliant. In the USEPA measurement mode the instrument rounds the readings to meet USEPA reporting requirements

Send Enquiry

Hi 847491 Haze Meter For Beer Quality Analysis

Hi 847491 Haze Meter For Beer Quality Analysis


  • Utilizes fast tracker—tag ID System
  • LED optical system
  • PC compatible via USB
  • GLP Features
  • Log on demand
  • Large, backlit LCD

 

The HI 847491 is an auto diagnostic haze in beer meter. HI 847491 is designed according to the ISO standard for haze in beer measurements.

This instrument compensates a beer color to guarantee accurate readings during the brewering process. The optical system consists of an LED and multiple detectors. A two, three or four point calibration can be easily performed at any time using the supplied or user prepared standards.

This meter has all the necessary GLP (Good Laboratory Practice) features to allow maximum traceability of data. Features include a real time clock, log on demand (up to 200 measurements), and Fast Tracker™ —Tag Identification System.

HI 847491 also incorporates a continuous measurement mode to measure the settling rate of suspended matter, and a signal average (AVG) mode to accumulate multiple readings giving a final average value. The average mode is particularly useful to measure samples with suspended particles with different dimensions.

HI 847491 features a user-friendly interface, with a large backlit LCD. Acoustic signals and display codes to guide the user step-by-step through routine operations.

Send Enquiry

Hi 847492 Haze Meter For Beer Quality Analysis

Hi 847492 Haze Meter For Beer Quality Analysis


  • Utilizes Fast Tracker—Tag ID System
  • LED optical system
  • PC compatible via USB
  • GLP Features
  • Log on demand
  • Large, backlit LCD

 

The HI 847492 is an auto diagnostic haze in beer meter. HI 847492 is designed, according to the ASBC (American Society of Brewing Chemists) standard for haze in beer measurements.

This instrument compensates a beer color to guarantee accurate readings during the brewering process. The optical system consists of an LED and multiple detectors. A two, three or four point calibration can be easily performed at any time using the supplied or user prepared standards.

This meter has all the necessary GLP (Good Laboratory Practice) features to allow maximum traceability of data. Features include a real time clock, log on demand (up to 200 measurements), and Fast Tracker™ —Tag Identification System.

HI 847492 also incorporates a continuous measurement mode to measure the settling rate of suspended matter, and a signal average (AVG) mode to accumulate multiple readings giving a final average value. The average mode is particularly useful to measure samples with suspended particles with different dimensions.

HI 847492 features a user-friendly interface, with a large backlit LCD. Acoustic signals and display codes to guide the user step-by-step through routine operations.

Send Enquiry

Hi 847493 Haze Meter For Beer Quality Analysis

Hi 847493 Haze Meter For Beer Quality Analysis


  • Utilizes Fast Tracker—Tag ID System
  • LED optical system
  • PC compatible via USB
  • GLP Features
  • Log on demand
  • Large, backlit LCD

 

The HI 847493 is an auto diagnostic haze in beer meter. HI 847493 is designed, according with the MEBAK (Central European Brewing Commission) standard requirements, for haze in beer measurements.

This instrument compensates a beer color to guarantee accurate readings during the brewering process. The optical system consists of an LED and multiple detectors. A two, three or four point calibration can be easily performed at any time using the supplied or user prepared standards.

This meter has all the necessary GLP (Good Laboratory Practice) features to allow maximum traceability of data. Features include a real time clock, log on demand (up to 200 measurements), and Fast Tracker™ —Tag Identification System.

HI 847493 also incorporates a continuous measurement mode to measure the settling rate of suspended matter, and a signal average (AVG) mode to accumulate multiple readings giving a final average value. The average mode is particularly useful to measure samples with suspended particles with different dimensions.

HI 847493 features a user-friendly interface, with a large backlit LCD. Acoustic signals and display codes to guide the user step-by-step through routine operations.

Send Enquiry

Hi 93414 Turbidity And Free/Total Cl2 Portable Meter

Hi 93414 Turbidity And Free/Total Cl2 Portable Meter


  • High accuracy at low ranges    
  • Exclusive chlorine CAL CHECK™ calibration validation
  • Exclusive Fast Tracker™ system
  • User replaceable light source
  • Two, three or four point turbidity calibration
  • USB and RS232 PC connectivity
  • GLP features
  • Logging for up to 200 readings
  • User friendly, backlit  display with guidance codes
  • Auto-off
  • Battery % on startup
  • Continuous current time on display

 

The HI 93414 measures the most important parameters of drinking water: turbidity and free/total chlorine. Designed for water quality measurements, HI 93414 provides reliable and accurate readings on low turbidity and chlorine values. The HI 93414 meets and exceeds the requirements of USEPA and Standard Methods both for turbidity and colorimetric measurements.

This instrument incorporates an optical system which guarantees accurate results. The optical system, consisting of a tungsten filament lamp, three detectors (scattered, transmitted for turbidimeter range and one for colorimeter range), and a narrow band interference filter @ 525 nm assures long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the lamp, making no need for frequent calibration. The 25 mm round cuvettes made from special optical glass guarantee repeatability and consistency of measurements.

Turbidity measurements can be made in the 0.00 to 1000 NTU (Nephelometric Turbidity Units) range. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Depending on the measured sample and needed accuracy, normal measurement, continuous measurement or signal averaging measurement can be selected. Free or total chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range.

At startup, the meter displays the percentage of remaining battery life and, if too low, a 'low battery' warning message is displayed.

With the powerful CAL CHECK™ function, performance of the instrument can be validated at any time by using the exclusive HANNA ready-made NIST traceable standards. Calibration can be performed at any time for turbidity and colorimetric range. For turbidity, a two, three or four-point calibration is available using supplied (<0.1, 15, 100 and 750 NTU adjustable calibration points) or user prepared standards. For colorimeter measurements, a one-point calibration can be performed.

HI 93414 has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked at the touch of a button. HI 93414 has a user-friendly interface with an easy to read, large (LCD). Displayed codes guide the user step by step with routine operation and through calibration. Confirmation and error acoustic signals aid the user during instrument operation.

For advanced field applications, the HI 93414 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.

With it’s logging function, up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).

Send Enquiry

Tturbidity Meter

Tturbidity Meter

  • High accuracy at low ranges (below 0.05 NTU)
  • Two, three or four point calibration
  • USB and RS232 PC connectivity
  • Log up to 200 records
  • GLP Features
  • User friendly, backlit  display with guidance codes
  • Battery % on startup
  • Continuous current time on display

 

The HI 98703 meets and exceeds the requirements of the USEPA Method 180.1 for wastewater and Standard Method 2130 B for drinking water. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.

This instrument incorporates complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points,
time and date can be checked at the touch of a button.

With it’s logging function, up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and

Exclusive Fast Tracker™

For advanced field applications, the HI 98703 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.

Send Enquiry

HI 93703 Portable Logging Turbidity Meter

HI 93703 Portable Logging Turbidity Meter

  • GLP Features
  • 3 point calibration
  • Logging for up to 199 measurements (HI 93703-11)
  • PC Connectivity (HI 93703-11)

 

HI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.

The HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.

HANNA instruments has chosen 10 FTU* as the calibration point because it is the value that best fits the water turbidity measurements in different applications, from drinking water to wastewater treatment. HANNA instruments uses the primary standard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a very toxic, unstable substance which requires particular care: its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life. HANNA AMCO-AEPA-1 standards are extremely stable, can be reused, and last up to six months if free from contamination. HI 93703 can be used with both standards.

The HI 93703-11 enhanced version features a real-time clock, logging for up to 199 measurements and PC compatibility via the RS232 interface and Windows® compatible HI 92000 software.

Both versions meet the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.

Send Enquiry

HI 93102 Complete Tool for Water Analysis


  • USEPA Compliance. In the turbidimetric mode, the HI 93102 uses the nephelometric principle according to USEPA’s 180.1 method and the Standard Method 2130B.
  • Custom Calibration Points. Advanced electronics allow operators to calibrate the meter at a selectable point in from 0.00 to 50.00 NTU.
  • Logging Capability. The HI 93102 makes it possible to log and retrieve up to 25 different samples.

 

The most important parameters needed for water analysis, especially in drinking water, can be measured with HANNA’s HI 93102 portable meter. This instrument not only measures turbidity, but also pH, total and free chlorine, bromine, iodine, iron, and cyanuric acid (CYS). Achieve laboratory results in the field quickly and easily.

Measurements are made quickly and repeatedly through a sophisticated, yet easy-to-use microprocessor. In colorimetric mode, users can select between factory preprogrammed calibration or calibrating the meter on their own, and measure either concentration or relative absorbance of the sample. Up to 25 measured samples can be stored in memory together with time and date. Miniaturization of the electronics has made it possible to offer unsurpassed accuracy and quality in a portable unit weighing just one pound!

Send Enquiry

Product
Showroom

View all our products / services as a slide show.

play now



Contact Us

Mr. Ganeshan A. C. (Manager)
No. 18- A - 1, Venkateshwara Apartment, Kalaivanar Street, New Perungalathur
Chennai, Tamil Nadu - 600 063, India
Telephone:  +(91)-(44)-22741058

Contact via E-mail

Contact via Mobile

Contact via SMS

Home  |  About Us  |  Our Products  |  Media Gallery   |  Site Map  |  Distributor Enquiry Form  |  Contact Us  |  Enquiry

Member IndiaMART.com © Linear Instruments. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry