We offer you high quality of portable instruments which are made by using superior quality of raw materials. It is made as per the industry standards and is made according to the specifications of the clients. It is available all across the globe to our clients. It is offered in varied ranges and is available at reasonable prices.
|
 | Digital Coating Thickness Guage | | |
| Product Name: Digital coating thickness gauge
Model: EQ-CM 8825FN
This Coating Thickness Meter is small in size, light in weight, easy to carry. Although complex and advanced, it is convenient to use and operate. Its ruggedness will allow many years of use if proper operating techniques are followed. Please read the following instructions carefully and always keep this manual within easy reach.
Features:
1.1 It meets the standards of both ISO2178 and ISO-2361. Suitable for the laboratory and for use in harsh field conditions.
1.2 The N probes measure the thickness of nonmagnetic coatings on non-magnetic metals. It is used on anodizing, varnish, paint enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.
1.3 Used the exclusive Micro-computer LSI circuit and crystal time base to offer high accuracy measurement fast measuring time.
1.4 Wide measuring range and high resolution.
1.5 Digital display gives exact reading with no guessing or errors.
1.6 The use of durable, long-lasting components, including a strong, light weight ABS-plastic housing assures maintenance free performance for many years. The housing Has been carefully shaped to fit comfortably in either hand.
6.4 If the instrument is not to be used for any extended period , remove batteries.
7. CALIBRATION FOILS As accessories, the instrument includes different foil set for different ranges. Please See the following table for reference.
7. Calibration Foils
As accessories, the instrument includes a different foil set for different ranges. Please see the following table.
| RANGE (um) | STANDARD FOIL INCLUDED | | CM25 | CM50 | CM100 | CM200 | CM500 | CM1000 | | 0 ~ 200 | X | X | X | X | | | | 0 ~ 500 | | X | X | X | X | | | 0 ~ 1000 | | X | X | X | X | X | | 0 ~ 2000 | | X | X | X | X | X | 8. Considerations
8.1 In order to weaken the influence of the measured material on the accuracy of measurement, it is recommended that the calibrations should be done on the uncoated material to be measured.
8.2 Probes will eventually wear. Probe life will depend on the number of measurements taken and how abrasive the coating is. Replacement separate can be fitted by qualified persons only.
| Range | 0~1250 um/0~50mil | | Resolution | 0.1 um (0~99.9um); 1 um (over 100um) | | Accuracy | 1~3%n or 2.5 um (Whichever is the greater) | | Power supply | 4 x 1.5 AAA) battery | | Operating condition | Temp. 0~50;Humidity <80% | | Size | 161x 69 x 32 mm (6.3 x2.7 x1.2 inch) | | Weight about | 260g including batteries | | Accessory | Carrying Case ........................... 1 pc. | | Operation Manual .................... 1 pc. | | Calibration Foils ......................... 1 set | | Substrate Iron ............................. 1 pc. | | Substrate (Aluminum)................... 1 pc. |
|
 | Digital Lux Meter | | |
| Product Name: Digital lux meter
Model: EQ-1301
Cost effective pocket size lux meter which measures lux intensity both in terms of Foot candle ( Fc) or lux (lx). Has the feature of low battery indication and peak hold.
Features
- 3 ½ digital LCD display
- Max Hold and Data Hold
- Auto Power Off
- Low battery indication User selectable Fc/Lux
Specifications
| Display | LCD 1999 Counts | | Measuring Range | 0 to 50,000 lux | | Accuracy | ±5% + 10d (< 10,000 lux) | | Repeatability | ±2% | | Measuring Range | 1.5 times/sec | | Auto Power off | After 15 min. of Inactivity | | Photo Detector | Silicon photo diode with filter | | Dimension | 188 x 64.5 x 24.5 (H x W x D) | | StorageeTnperature | -10 to 65C at < 80% RH | | Power Supply | 1 x 1.2 VBatte/ | | Weight | 160gms | For more details, click the given below attachment.
|
 | High Intensity Lux Meter | | |
| Product Name: high intensity lux meter
Model: EQ-1308
Instrument is easy to use with light weight, providing accurate display light level in terms of foot candles (FC) or LUX over wide range. Just turning the function switch to select the "Lux" scale and thin Exposing the photo detector to light source in a horizontal position, thus the meter will display illuminance on LCD Display.
Features
• LCD display counts • Auto Ranging • Analog bargraph / segments • Peak Hold • Relative mode • Max and Data Hold • Auto Power Off • Low battery indication • User selectable FC / Lux
Specification
| Max Range | 4,00,000 Lux | | Accuracy | ± 5% ± 10d (< 10,000 Lux) | | ± 10% ± 10d (> 10,000 Lux) | | Max Resolution | 0.1 lux/Fc | | Measuring Rate | 1.5 times / second | | Photo Detector | 115mm X 60mm x27mm | Meter Size (HxWxD): 165mm x 76mm x 43mm
Weight: 403g
Accessories : One 9V battery and One Photo Detector.
For more details, kindly click on the given below attached file.
|
 | High Temp IR Thermometer | | |
| Product name: High temp IR thermometer
Model no: EQ-8859 Features
- High 50:1 distance to Spot ratio
- Measuring range of - 50.0 to 1600°C
- Built-in laser pointer
- Automatic data hold
- Max. Min, DIF. AVG, record
- High and Low alarm
- Adjustable emissivity between 0.1 to 1.0
- Trigger Lock
Application
- Plastic Moulding
- Foundry
- Asphalt
- HVACR
Specifications
| Range | -50°C to1600°C | | Response time | Less than 1 second | | Resolution | 0.1 0C | | Basic Accuracy | -20 to 538 : ± 1 % of reading ± 2°C 538 to 1600°C : ± 3.5% ±50C | | Optional Resolution | 50 ; 1 distance to spot size | | Emissivity | Adjustable 0.10 to 1.0 | | Spectral Response | 8 - 14µm | | Power Supply | 9V battery | For more details, kindly click with the below attached link.
|
 | High Temperature IR Thermometer | | |
| Product name: High temperature IR thermometer
Model: EQ-8839
Features :
- High distance to target ratio to measures smaller surface areas at greater distances.
- Widest Temperature Range from -50.0 to 1000°C.
- Built-in laser pointer.
- °C/°F Switchable Button
- Automatic Data Hold & Auto Power off.
- Max, Min, DIF, AVG, record.
- Backlit LCD display.
- Adjustable emissivity.
Application
- Plastic Moulding
- Foundry
- Asphalt
- HVACR
Specification
| Display | 3-14 digit LCD with Backlighting | | Range | -50°C to 1000°C | | Basic Accuracy | ± 1.5% of reading | | Resolution | 0.1 °C | | Optical Resolution | 50:01:00 | | Power Off | Automatic shut off after 7 seconds, approx. | | Emissivity | Adjustable 0.10 ~ 1.0 | | Battery | 9V battery | | Dimension | 230 x 100 x 56mm | | Weight | 290g. | For more details, kindly click the given below attached file.
|
 | Infrared Thermometer (ST-8806H) | | |
| Product name: infrared thermometer
Model: ST-8806H
The non-contact body infrared thermometer is designed for body surface & forehead temperature measurement for infants & adults without contact to Human Body. It can be used by consumers in household environment & doctor in clinic as reference. It is manufactured in accordance with the ASTM 1965-1998 Standard Specification for infrared thermometers for intermittent determination of patient temperature.
The non-contact body infrared thermometer can also be used to measure the temperature of a baby-bottle or bath, or room temperature (by using the surface temp. function). This function is in accordance with the Directive 89/336/EEC Electromagnetic Compatibility.
FEATURES:
- Precise Non-Contact Measurements
- User Selectable °C or °F
- Selectable Body & Surface Temp.
- Set Alarm Value
- Automatic Data Hold & Auto Power Off
- Automatic Selection Range & Display Resolution 0.1°C (0.1°F)
- Backlight LCD Display
TECHNICAL SPECIFICATION :
| • Measuring Range | | In Body Mode | 32.0to42.50°C | | In Surface Temp Mod | 0 to 60°C | | Consumption | <50mW | | Accuracy | ±0.3°C | | Measuring Distance | 5cm-15cm | | Automatic Stop | 7 sec |
| Other Specification | | Display Resolution | 0.1°C | | Operating Temperature | 10 to 40°C | | Humidity Range | <85% | | Power | 2 x '" Batteries | | Size | 149x77x43mm(LxWxH) | | Weight | Gross 400g/Net 172g |
| Non-contact Body Infrared Thermometer Precision | | 32 to 35.9 °C | ± 0.3°C | sAccording to ASTM Standard E1965-1998 (2003) | | 36 to 39 °C | ± 0.2°C | | 39 to 42.5 °C | ± 0.3°C | For more details, kindly click the given below attached file.
|
 | Digital Refractro Meter | | |
| Product name: digital refractors meter
Model: eq-ref-121-122-123
Feature
• 2-in-l Measurement: % brix & refractive index • Alarm of low voltage • Automatic temperature compensation • Automatic shut off
Model: eq-ref-121 /122/123
| Specification | ref-121 | ref-122 | ref-123 | | •Measuring range | 0~45% brix nd1. 3330-1. 3903 | 28~65% brix nd1. 3800- 1. 4535 | 60~92% brix nd1. 4400-1. 5230 | | •Accuracy | ±0. 1% ±0. 0002 | | •Resolution | 0. 1% 0. 0001 | | •Operation temperature | 0~40°c(32~104°f) | | •Storage temperature | -10~50°c(14~122°f) | | •Power supply | 1 battery9v | | •Size(mm) | 185mm x 105mm x 50mm | | •Weight | 250g | operation
1. Starting up: Press on/off key, the digits appeared represent current environmental temperature.
2. Zeroing(orreference): Use pure water,ortiter:clean liquid pool, drop right amount of water, press "adj" key, "ref' is displayed. Then "ref" is changed to "end" release "adj" key, now zeroing is finished.
3. Test: Mop up liquid pool with clean paper, then drop in liquid to be measured. Press "read" key lightly. The displayed reading value is the concentration value of the measured liquid. (pressing time should be not more than 3 seconds).
4. Conversion: When you need to measure other properties (such as refractive index) of a kind of solution, you should convert "concentration" in window to "refractive index". Please press "adj" & "read" keys by forefinger and middle finger of right hand respectively under status of shut down; at the same time, click "on/off" key with finger of left hand, now refractive index value is displayed. If you want to resume, perform the same operation after shut down. Conversion operation of other series is the same as this. Please refer to figure below.
|
 | Digital Tachometer Contact / Non Contact Type | | |
| Product Name: Digital Tachometer Contact / Non Contact Type
Model: EQ-811B
FEATURES:
- Multiple measurements : RPM, Velocity, M/Min. and length in Meters.
- Minimum, Maximum, Last Value Memory
- Low Battery Indicator.
- Wide Measuring range from 2.5 to 100000 RPM
- Large Display LCD
APPLICATION :
Non-contact RPM Measurements for Flywheels, Motors Conveyors and Pumps etc.
Model : EQ-811B
SPECIFICATION :
| Display | 5 digits, 18mm (0.7") LCD (Liquid Crystal Display) | | Measuring Range | 2.5 to 99,999 RPM (r/min). | | Resolution | 0.1 RPM (2.5 to 999.9 RPM). 1 RPM (over 1,000 RPM). | | Accuracy | ± (0.05%+1 digit). | | Sampling Time | 0.8 sec. (over 60 RPM). | | Range Select | Automatic. | | Memory | Last value, Max. Value, Min. Value. | | Detecting Distance | 50 to 200mm/2 to10 inch (LED) | | | 50 to 500mm/2 to 20inch (Laser) | | Time Base | Quartz crystal. | | ACCESSORIES | Carrying Case......................................................... 1 pc. Reflective Tape (600mm)..................................... 1 pc. Operation Manual.................................................. 1 pc. Contact Rotational Speed Measuring Fitting........ 3 pcs. Contact RPM Measuring Fitting.......................... 1 pc. | For more details kindly click with the given below attached file.
|
 | Mini Sound Level Meter | | |
| Product name: Mini sound level meter
Model: EQ-805
FEATURES
- Meets IEC 651 type 2 standard
- Extremely Cost Effective
- Max Hold and Data Hold Function
- High Performance
- Compact & New Design
SPECIFICATIONS
| Display | 4 digit LCD | | Microphone | ½' elected condenser Microphone | | Range | 35 to 130dB | | Frequency weighting | A and C | | Resolution | 0.1dB | | Accuracy | ± 1.5dB | | Operating Frequency | 31.5Hz to 8KHz | | Time Weighting | Fast and slow | | Level Ranges | Lo ( 35 to 100dB ) ; Hi (65 to 130dB ) | | Storage Temperature | -10°C to 60°C ( < 80% RH) | | Over Range | "OL" mark Indication | | Size ( H x W x D) | 210 mm x 55mm x 32 mm | | Weight | 230 g | Accessories : 9V battery, Carrying case and Manual.
For more details kindly click with the given below attached file.
|
 | Handheld Digital Thermometer | | |
| Product Name: Hand held digital thermometer
Model: EQ-610B
EQ-610B is a digital thermometer offers fast response and better accuracy in contact type temperature measurement. It is protected by a rugged holster. Large LCD display with back light.
Features
- 0.1&1.0 C switchable resolution
- Low battery indication
- Data Hold function
- Rugged holster Protection.
- Selectable0 C / °F / K Temperature Display
Specifications
| Display | 3 ½ digit LCD | | Measurement Range | - 50 to 1300 0C | | Accuracy | ± 20 : - 50 to 00 | | ± 0.5% rdg + 10 : 0 to 1300 0 | | Sampling Rate | 2.5 times per sec. | | Operating Temperature | 0 to 500C | | Input Protection | 60 VDC or 24 V rms | | Power Supply | 9V Battery | | Dimension | 165 x 76 x 43mm | | Weight | 400gm | Accessories : 9V battery, Holster with stand and Bead yTpe Temperature probe.
For more details kindly click with the given below attached file.
|
 | Hygro - Thermometer | | |
| Product name: Hygro - Thermometer
Model: EQ-308,309,311
Feature :
- Display temperature, humidity & time simultaneously.
- Memory of Max & Min measuring value.
- 12-hour / 24-hour displaying system selectable.
- 0C/F0 unit selectable.
- Alarm function. Clock function.
- Desk-top placing or Wall Hanging.
Specification :
| Range | Temperature : -50 to 70°C | | Humidity : 10 to 99 % RH | | Accuracy | Temperature : ± 1 °C | | Humidity : ± 5%RH | | Power Supply | 1 .5V (AAA size) x 1 | | Product Dimension | 100 x 108 x 20mm | | Weight | Approx. 160g | | Storage Condition | -2°C~6°C, 2°~80%RH | For more details kindly click with the given below attached file.
|
 | Digital Vibrationmeter | | |
| Product Name: Digital vibration meter
Model: EQ-VM6360
Features:
- Specially designed for easy on site vibration measurement of all rotating machinery for quality control, commissioning,and predictive maintenance purposes.
- Individual high quality accelerometer for accurate and repeatable measurements
- Bearing condition monitoring function
- LCD digital display
- ' Light weight and easy to use
- Wide frequency range (10Hz. to 10kHz.) in acceleration mode
- Automatic power shut off to conserve power.
- Ac output socket for head phones and recording.
- Optional head phones for use as electronic stethoscope.
- Optional software and cable for RS232 Cinterface.
Specification:
| Display | 4digits,18mm LCD | | Transducer | Piezoelectric Accelerometer | | Measuring Parameters | Velocity, Acceleration, and Displacement | | Multi functional type | RPM and Frequency besides parameters mentioned above. | | Measuring range | | | Velocity | 0.01-19.99cm/s | | Acceleration | 0.1-200.0m/s | | Displacement | 0.001-2.000mm | | RPM(r/min) | 60-99,990RPM | | Frequency | 1 -20kHz Frequency range | | Accuracy | ±5% + 2digits Metric/Imperial conversion | | Output | AC output 2.0V peak full scale (load resistance: above 10k) |
| PC Interface | RS232C interface (Cable and Software is not included) | | Power Supply | 4x 1.5AAA size(UM-4) batteries | | Power off | Manual off at any time or Auto power off after 5 minutes from last key operation | | Operating Conditions | Temperature:0t o50°C Humidity :Below90%RH | | Dimensions | 124 x62 x30mm | | Weight | 120g(not including batteries) | Accessories Included:
- Powerful Rare Earth Magnet..........................1 pc.
- Carrying Case............................................1 pc.
- Operation Manual .................................1pc.
Optional Accessories:
Headphones for use as Electronic Stethoscope Cable and software for RS232C
For more details kindly click with the given below attached file.
|
 | Ultrasonic Thickness Gauge | | |
| Product name: ultrasonic thickness gauge
Model: EQ-TM8812
This thickness meter is small in size, light in weight, easy to carry. Although it is an advanced model, it is convenient to use and operate.
FEATURES:
The high power of emission and broad band of receiving sensitivity makes it easy to measure the rough surface, even on cast iron. Applicable to measure the thickness of many materials, e. g. Steel, Cast iron, Aluminum, Red Copper, Brass, Zinc, Quartz glass, Polyethylene, PVC, Gray Cast Iron, Nodular Cast Iron etc. Automatic power off to conserve power. Can communicate with PC computer for statistics and printing by the optional cable the software for RS232C interface.
APPLICATION :
Used for measuring thickness and corrosion of pressure vessels, chemical equipment, boilers, oil storage tanks, etc., in Industries of petroleum, shipbuilding, power station and machine manufacturing, etc..
SPECIFICATION :
| Display | 4 digits, 10 mm LCD | | Range | 1.2 ~ 200mm | | Resolution | 0.1 mm/0.001 inch | | Accuracy | ±0.5% + 0.1 | | Sound Velocity | 1000 ~ 9000 m/s | | Power Supply | 4 x 1.5 V AAA battery | | Operating condition | Temp. 0 ~ 50 °C | | Humidity | <90%RH | | Size | 120 x 62 x 30mm | | Weight | About 260g (including batteries) | | ACCESSORIES | Carrying Case.....................................1 pc. Operation Manual.............................1 pc. Ultrasonic Sensor........................1 pc. | For more details kindly click with the given below attached file.
|
 | Shore Hardness Tester -A | | |
| Product Name: Shore hardness tester -A
Model: EQ-HT-6510A
APPLICATION :
Shore A is designed to measure the penetration hardness of rubber, elastomers and other rubber like substances such as neoprene, silicone, and vinyl. It can also be used for soft plastics, felt, leather and similar materials.
Features :
- Digital Durometer for Shore Hardness Testing
- Pocket size with Integrated Probe
- High Accuracy Measurement.
- Digital LCD display.
- Max. Hold Key.
- Indicator of maximum value.
- Zero Calibration Check.
- RS-232C Interface.
- Automatic Power Off to conserve power.
- Low Battery Indicator
For more details kindly click with the given below attached file. |
 | Humidity And Temperature Meter | | |
| Product name: humidity and temperature meter
Model: eq-615
Eq 615 is a combined temperature & humidity measuring instrument which also has the facility to use external k type thermocouple to measure temperature up to 1000c. Dual display large lcd display will give both readings of temperature & humidity.
Features: - Dual display of %rh & c
- Large lcd display with back light
- Max / data & hold functions
- Low battery indication
- External 'k' type t/c can be used
|
 | Infrared Thermometer | | |
| Features : - Built-in laser pointer
- °C / °F Switchable Button
- Automatic Data Hold & Auto Power off
- Back lit LCD display
- Display Hold Function
Application : - Plastic Molding
- Asphalt
- HVACR
Specification : - Measuring Range : -20 ~ 530°C (-4~986°F)
- Accuracy : ±2% or 2 °C
- Resolution : 0.1 °C
- Distance to Spot : 12 : 1
- Spectral Response : 5 to 14µm
- Operating Temp. : 0 to 50°C (32 to 122°F)
- Storage Temp. : -20 to 65°C; 10% to 90% RH
|
 | Digital Thermometer | | |
| Model: EQ-801
Features: - Compact with LCD display
- Extended 5" length probe
- ºc/ºf Read out
- Last measurement memory
- Data hold option
- Auto Power off
- Battery operated
Specification:
| Temperature range: | -50~250ºC ±1ºC -58~482ºF ±2ºF
| | Probe Dimension: | 5" Length X 1/8 mm | | Dimension | 129 X 18 X 18 mm | | Operating Power Supply | 1.5v battery | | Weight | Approx.58 g |
|
 | Multi-range Conductivity Meters | | |
| Designed for QC and Production
HI 8633 and HI 8733 have been designed specifically for use in areas of production and quality control. It is often necessary to test samples ranging from deionized water to brine. Using an amperometric system would require constant recalibration and probe changes, thus making the measurement process time consuming and burdensome. To solve this problem, HANNA has developed the HI 8633, which uses a 4- ring potentiometric probe. The rugged probe is made of PVC, which is ideal for indoor and outdoor measurements. Using one point calibration, it is now possible to obtain accurate readings across a very wide range, from 0.1 to 199.9 mS/cm.
|
 | EC And Resistivity Meter | | |
| EC and resistivity in a Watertight
HI 87314 is a combination, portable meter that can read conductivity in 4 different ranges and resistivity.For conductivity measurements, the calibration is a simple 1 point procedure via a trimmer located in the battery compartment. The supplied probe does not require recalibration when switching from one range to another. The 4- ring (stainless-steel) probe has a built-in temperature sensor that automatically compensates for temperature changes.The temperature coefficient can be adjusted from 0 to 2.5% using a knob on the front panel.
|
 | EC, TDS And Temperature Meters | | |
| Designed for QC and production
HI 8730, HI 8731 and HI 8732 are complete, versatile and watertight conductivity meters that are lightweight and easy to maintain.HI 8730 measures EC in the 0 to 1990 µS/cm range, TDS from 0 to 1990 ppm,and temperature from 0 to 70°C.HI 8731 measures EC and TDS with extended ranges (from 0 to 6000 µS/cm and from 0 to 3000 ppm, respectively) and temperature from 0 to 70°C.HI 8732 measures EC in the 0 to 4 mS/cm range, TDS from 0 to 1999 ppm and temperature from 0 to 70°C.Each desired measurement mode features its own key for quick selection. |
 | TDS And EC Meters | | |
| Choose the model with the measurement range that best fits your application: HI 86301: TDS from 0 to 1999 ppm (mg/L) HI 86302: TDS from 0.00 to 10.00 ppt (g/L) HI 86303: EC from 0 to 1999 µS/cm HI 86304: EC from 0.00 to 19.99 mS/cm |
 | TDS Meter | | |
| HI 8734 has not only been specifically designed for the water conditioning industry, but particularly in the softening, demineralization, reverse osmosis and drinking water applications. Three ranges of measurement ensure the highest accuracy possible. All three ranges can be executed at the touch of a button, without having to change the conductivity probe. This makes it verye easy to switch applications without having to worry about recalibration.To add to the meter's accuracy and efficiency, Manual Temperature Compen- sation is possible using a knob on the front panel. For the best protection in the field, the 4- ring potentiometric probe is made of rugged PVC. To access difficult areas, the probe is supplied with a 1m (3.3') cable.
|
 | Dissolved Oxygen Meter | | |
| HI 9146 is a water-resistant, microprocessor-based, Dissolved Oxygen meter with automatic calibration and temperature compensation (ATC).D.O. measurements can be displayed in parts per million (ppm=mg/L) or in %saturation. The temperature range is indicated in Celsius from 0 to 50°C with 0.1 resolution. The HI 9146 also allows manual compensation of altitude and salinity values. The petrographic probe, supplied with the instrument is provided with a protective cover for the membrane. A HOLD button allows the user to freeze the reading on the LCD. HI 9146 can be powered with batteries (with low battery indicator) or through a12 Vdc adapter.
|
 | Extended Range pH Meters | | |
| No-nonsense approach to pH Measurement
HI 991003 is provided with our unique sensor check™ feature that allows the user to establish pH probe status before performing measurements. HI 991002 reads pH, ORP and temperature
HI 991002 reads pH, OR and temperature. |
 | Plating Bath pH Meter | | |
| Built tough for industrial applications
Hi 99131 i a waterproof, portable ph and temperature meter ideal for use in plating baths. Hi 62911 double junction ph probe included) utilizes proven recessed flat-tip technology for long-life. the recessed flat tip is easy to clean and prevents solids in solutions from collecting on the sensor. The titanium body functions as a potential matching pin for increased stability of readings and an extended sensor life. The probe tip incorporates an annular PTFE junction that maximizes surface contact to enhance response and stability. Additionally, the integrated temperature sensor eliminates the need for an external probe.
|
 | Boiler And Cooling Tower PH Meter | | |
| HI 72911 double-junction pH probe(include)has a flat tip sensor in an unbreakable stainless steel body. The flat tip sensor is easy to clean and prevents solids in solutions from collecting on the sensor. This probe features a large annular PTFE junction for maximum surface contact which provides increased response and stability. This advanced electrode also contains an integral temperature sensor and a pre-amplifier to reduce electrode noise and intererence. The meter reads from -2 to 16 pH, while simultaneously showing the temperature in °C or °F. Graphic icons guide opera-tions. A stability indicator with HOLD feature determines when to freeze the reading for easy record keeping. |
 | Leather And Paper pH Meter | | |
| Production and packing area portablility
Direct pH measurement on paper and leather is fast and accurate with the HI 99171 pH meter, HI 99171 utilizes a flat tip probe designed to optimize surface contact with the sample.pH measurement of papers and cartons is important, not only in the production phase, but also in the packaging phase.The food industry, for example,performs many compatibility tests; one of theses pH.Measurements are automatically compensated for the effects of temperature and the LCD continuously displays the samples current temperature.All operations can be simply performed with 2 buttons; messages and symbols are displayed to guide the user through measurement and calibration procedures.
|
 | Slim pH Meter | | |
| Top performance in a sleek, lightweight design
The hi 8424 portable ph meter is one of the most popular ph meters on the market. By utilizing an advanced, custom Microprocessor, hi 8424 is able to perform ph, orp and temperature measurements with high accuracy and fast response. The mv measurements auto-range and change resolution from 0. 1 to 1 mv when readings reach ±699. 9 mv. Ph slope changes due to temperature variation are automatically or manually compensated for, from -20 to 120°c (-4. 0 to 248. 0°f).
|
 | pH/ mV / C Meter | | |
| Attach a plotter or recorder directly
For a hard copy of the measured values,two recorder output terminals on the front panel make it possible to attach a plotteror recorder directly to the meter.The large LCD displays a pH or mV to indicate the operational mode in use.Pressing the 'HOLD' key will freeze the reading on the display. Calibration is performed simply through two trimmers on the front panel.The HI 721311 optional accessory kit includes a rugged carrying case, pH 4 and pH 7 buffer solutions and screwdriver.
|
 | pH/mV/Temperature Meter | | |
| Make sure your electrode is a top performer!
Environmental or mechanical problems often affect ph measurements. Typically, in these conditions, ph meters give a false ph 7 reading. In most applications, ph 7 is the expected value, therefore the user is not aware of the problem.
Examples of a false ph 7 reading:
• The glass bulb of the ph electrode is broken • Loss of signal (up to hundreds of meg ohms) of the electrode/meter connection cable, due to environmental humidity • Cable or connector short circuit
|
|
 Product Showroom View all our products / services as a slide show. play now

|