Multiparameter Bench Meter

Share: FacebookTwitterStumble

We are the leading manufacturer of multiparameter bench meter which are made by using superior quality of raw materials and are available at very reasonable prices all across the globe to our clients. It is known for its durability and reliability. It is economical and very safe to use. It is effective and efficient. It is corrosion resistant and can work under the harsh environment. It is easy to clean.



HI 4522 Research Grade Meter

HI 4522  Research Grade Meter

  • Up to eight measurement parameters
  • Two input channels pH/ORP/ISE and EC/TDS/Resistivity/Salinity
  • pH Calibration Check™
  • Five point pH and ISE calibration with standard and custom buffers
  • USP 645 method, ISE incremental methods and salinity scales
  • Fully customizable
  • Large log memory with different  logging methods

 

HI 4522 is a research grade, benchtop instrument that feature 8 measurement ranges: pH, ORP (Oxidation Reduction Potential), ISE, conductivity, resistivity, TDS, salinity and temperature. This instrument incorporates dual channels with a separate temperature input and support the external reference electrodes required by half cell pH and ISE sensors.

The user interface is customizable and capable of displaying two channels at the same time, showing the measurements in various modes: basic measurement with or without GLP information, graph or logging data.

This instrument offers multi-language support and contextual help is available through a dedicated Help key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through all measurement and calibration procedures to ensure measurements and calibrations are performed properly.

HANNA’s pH Calibration Check™ diagnostics system ensures accurate readings every time by alerting users of potential problems during the calibration process. The Calibration Check™ system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH buffer solutions. After the guided calibration process, electrode condition is evaluated and an indicator is displayed  informing the user of the overall pH?electrode status.

Automatic, semiautomatic and manual pH calibration is available in up to five points, with eight standard (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) and up to five custom buffers. The Out of Calibration Range and Cal Due features alert the user in the event the measurement is far from the calibration point or when the meter is due for recalibration. Proper, scheduled calibrations are crucial for accurate and repeatable measurements.

HI 4522 features up to five point Manual Selection and Custom Standard ISE calibration with up to five standard solutions and up to five custom solutions with or without temperature compensation. From the on-screen list, users can select their ISE electrode parameter along with it’s standard configuration profile or create their own.

Up to a four point automatic or custom standard conductivity calibration can be performed in up to four points as well as probe cell constant. One fixed point salinity calibration can be performed on the Percent Scale only. Three salinity ranges are available: practical scale, natural sea water scale and percentage scale.

Up to ten profiles can be saved and recalled eliminating the need to reconfigure each time when a different probe is used. User definable configurations can include: temperature compensation in accordance with each parameter, isopotential points for pH and ISE, measurement units of ISE concentrations and ISE electrode type, temperature units, EC temperature reference, EC temperature coefficient, EC probe type, and cell constant.

Three selectable logging modes are available: Automatic, Manual and AutoHold logging. Up to 100 logging lots with up to 10,000 recods each can be stored for automatic or manual modes along with up to 200 USP reports, and up to 100 ISE methods reports. Automatic logging features a selectable area and sampling period while GLP information includes complete data about user calibration of each parameter and identification information for the instrument, user, and company. Data can be transferred to a PC via the opto-isolated RS232 or USB ports and HI 92000 software (optional).

Send Enquiry

HI 4521 Research Grade Meter

HI 4521 Research Grade Meter

  • Up to eight measurement parameters
  • Two input channels pH/ORP and EC/TDS/Resistivity/Salinity
  • pH Calibration Check™
  • Five point pH calibration with standard and custom buffers
  • USP 645 method and salinity scales
  • Fully customizable
  • Large log memory with different  logging methods

 

HI 4521 is a research grade, benchtop instrument that features 7 measurement parameters: pH, ORP (Oxidation Reduction Potential), conductivity, resistivity, TDS, salinity and temperature. This meter incorporates dual channels with a separate temperature input and support the external reference electrodes required by half cell pH sensors.

The user interface is customizable and capable of displaying two channels at the same time, showing the measurements in various modes: basic measurement with or without GLP information, graph or logging data.

This instrument offers multi-language support and contextual help is available through a dedicated Help key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through all measurement and calibration procedures to ensure measurements and calibrations are performed properly.

HANNA’s pH Calibration Check™ diagnostics system ensures accurate readings every time by alerting users of potential problems during the calibration process. The Calibration Check™ system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH?buffer solutions. After the guided calibration process, electrode condition is evaluated and an indicator is displayed  informing the user of the overall pH electrode status.

Automatic, semiautomatic and manual pH calibration is available in up to five points, with eight standard (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) and up to five custom buffers. The Out of Calibration Range and Cal Due features alert the user in the event the measurement is far from the calibration point or when the meter is due for recalibration. Proper, scheduled calibrations are crucial for accurate and repeatable measurements.

Up to a four point automatic or custom standard conductivity calibration can be performed in up to four points as well as probe cell constant. One fixed point salinity calibration can be performed on the Percent Scale only. Three salinity ranges are available: practical scale, natural sea water scale and percentage scale.

Up to ten profiles can be saved and recalled eliminating the need to reconfigure each time when a different probe is used. User definable configurations can include: temperature compensation in accordance with each parameter, isopotential points for pH, temperature units, EC temperature reference, EC temperature coefficient, EC probe type, and cell constant.

Three selectable logging modes are available: Automatic, Manual and AutoHold logging. Up to 100 logging lots with up to 10,000 recods each can be stored for automatic or manual modes along with up to 200 USP reports. Automatic logging features a selectable area and sampling period while GLP information includes complete data about user calibration of each parameter and identification information for the instrument, user, and company. Data can be transferred to a PC via the opto-isolated RS232 or USB ports and HI 92000 software (optional).

Send Enquiry

HI 4222 Research Grade Meter

HI 4222 Research Grade Meter

  • Two input channels (pH/ORP/ISE)
  • pH Calibration Check™
  • Five point pH and ISE calibration with standard and custom buffers
  • Fully customizable
  • GLP features
  • Large log memory with different logging methods

 

HI 4222 is a research grade pH, ORP and temperature benchtop meter. This instrument incorporates dual channels with a separate temperature input and support the external reference electrodes required by some pH and ISE sensors.

The customizable user interface can display two channels at the same time, showing the measurements in various modes: basic measurement with or without GLP information, graph or log history.

These instruments offer multi-language support and contextual help is available through a dedicated Help key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through all measurement and calibration procedures to ensure measurements and procedures are performed properly.

HANNA’s pH Calibration Check™ diagnostics system ensures accurate readings every time by alerting users of potential problems during the calibration process. The Calibration Check™ system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH buffer solutions. After the guided calibration process, an electrode condition indicator is displayed on the LCD informing the user of the overall pH electrode status.

Automatic, semiautomatic and manual pH calibration is available in up to five points, with eight standard (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) and up to 5 custom buffers. The Out of Calibration Range and Cal Due features alert the user in the event the measurement is far from the calibration point or when the meter is due for recalibration. Proper, scheduled calibrations are crucial for accurate and repeatable measurements.

This instrument also features up to five point Manual Selection and Custom Standard ISE calibration. From the on-screen list, users can select their ISE electrode parameter along with it’s standard configuration profile or create their own.

Up to a four point automatic or custom standard conductivity calibration can be performed in up to four points as well as probe cell constant

Up to 10 profiles can be saved and recalled, eliminating the need to reconfigure each time when a different electrode is used. User definable configurations can include: temperature compensation in accordance with each parameter, ISO-potential points for pH and ISE, measurement units of ISE concentrations and ISE electrode type, temperature units. Three selectable logging modes are available: Automatic, Manual and AutoHold logging. Up to 100 logging lots can be stored for automatic or manual modes along with up to 200 USP reports, and up to 100 ISE methods reports. Automatic logging features a selectable area and sampling period while GLP information includes complete data about user calibration of each parameter and identification information for the instrument, user, and company. Data can be transferred to a PC via the opto-isolated PC interface via the RS232 or USB ports and HI 92000 software (optional).

Send Enquiry

Product
Showroom

View all our products / services as a slide show.

play now



Contact Us

Mr. Ganeshan A. C. (Manager)
No. 18- A - 1, Venkateshwara Apartment, Kalaivanar Street, New Perungalathur
Chennai, Tamil Nadu - 600 063, India
Telephone:  +(91)-(44)-22741058

Contact via E-mail

Contact via Mobile

Contact via SMS

Home  |  About Us  |  Our Products  |  Media Gallery   |  Site Map  |  Distributor Enquiry Form  |  Contact Us  |  Enquiry

Member IndiaMART.com © Linear Instruments. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry