We are the leading manufacturer of bench top new products which are made by using superior quality of raw materials and is available at very reasonable prices all across the globe to our clients. It is known for its durability and reliability. It is economical and very safe to use. It is effective and efficient. It is designed for the simplicity of use in all application where efficiency and quickness is required.
|
 | pH 20 Easy-Use Basic pH Benchtop Meter | | |
| - Easy to use meter for performing specific measurements
- Automatic pH calibration
pH 20 is a basic pH meter designed for simplicity of use in all applications where fast and efficient daily controls are required. This meter is also suitable for the educational field, where students are often first introduced to measuring instruments. This model measures pH in the 0 to 14 range, with 0.01 resolution. The pH calibration procedure is automatic and can be performed at one or two points. Readings can be manually (MTC) or automatically (ATC) compensated for temperature. The automatic temperature compensation is performed if using the optional HI 7662 temperature probe, while for manual compensation the user can set the temperature value through the arrow keys. The meter is also provided with the HOLD function, which allows to freeze reading on the LCD by simply pressing the HOLD button. Order Information: pH 20-01 (115V) and pH 20-02 (230V) are supplied with HI 1110B pH electrode, 12 VDC adapter and instructions. - Specifications
- MSDS
- Accessories
- Downloads
| Range | pH | 0.00 to 14.00 pH | | Temperature | 0.0 to 100.0°C | | Resolution | pH | 0.01 pH | | Temperature | 0.1°C | | Accuracy | pH | ±0.02 pH | | Temperature | ±1°C | | Temperature Compensation | | manual (adjustable with arrow keys) or automatic from 0 to 100°C (with temperature probe) | | Probe | | HI 1110B pH electrode (included); HI 7662 temperature probe (optional) | | pH Calibration | | automatic, 1 or 2 point (pH 4.01, 7.01, 10.01) | | Power Supply | | 12 Vdc adapter (included) | | Environment | | 0 to 50°C (32 to 122°F); RH max 95% | | Dimensions | | 230 x 170 x 75 mm (9.1 x 6.7 x 3.0") | | Weight | | 500 g (1.1 lb.) | |
 | Hi 208 PH Meter With Built In Magnetic Stirrer | | |
| - Compact and lightweight
- Built-in beaker and beaker-top electrode holder
- pH and temperature in one probe
- Built-in magnetic stirrer
- Dual-level LCD
- Automatic calibration
- Operated by battery or 12 VDC
- °C and °F temperature scales
With features such as a built-in beaker holder, beaker-top electrode holder and rugged, 2-in-1 pH and temperature sensor, the HI 208 is designed to meet busy classroom environments. This instrument also features an extended pH range, dual-level LCD with icons for stability and buffer recognition, built-in magnetic stirrer, automatic pH calibration, and temperature display in either Celsius or Fahrenheit. In addition, all readings are automatically compensated for temperature variations. In the classroom, this compact unit reduces clutter and utilizes a minimal amount of space on the desktop. Switch to battery power and the instrument can be taken outside the classroom for field studies. When lab time is over, the instrument is easily cleaned and can be placed out of the way—right away. (*) The temperature range is limited to 80 °C (176 °F) if using the HI 1291D probe. Order Information: HI 208-01 (115V) and HI 208-02 (230V) are supplied with HI 1291D pH electrode, HI 740035 pH electrode holder and plastic beaker, rubber O-ring, magnetic stir bar, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, 12 VDC adapter, battery and instructions. - Specifications
- MSDS
- Accessories
- Downloads
| Range | pH | -2.00 to 16.00 pH |
| Temperature | -5.0 to 105.0°C or 23.0 to 221.0°F | | Resolution | pH | 0.01 pH |
| Temperature | 0.1°C or 0.1°F | | Accuracy | pH | ±0.02 pH |
| Temperature | ±0.5 (up to 60°C); ±1°C (outside) ±1°F (up to 140°F); ±2°F (outside) | | Calibration | pH | Automatic 1 or 2 points with 2 sets of memorized buffers (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18) | | Temperature Compensation | | Automatic from -5.0 to 105.0°C (23.0 to 221.0°F) | | pH Electrode | | HI 1291D with built-in temperature probe (included) | | Power Supply | | 12 VDC adapter (included) | | Battery Type / Life | | 9V / approximately 500 hours of continuous use (without stirrer) | | Environment | | 0 to 50°C (32 to 122°F) 95% RH | | Dimensions | | 192 x 104 x 134 mm (7.5 x 4.1 x 5.3’’) | | Weight | | 420 g (14.8 oz.) | |
 | Hi 207 PH Meter For Education | | |
| - Compact and lightweight
- Built-in beaker and beaker-top electrode holder
- pH and temperature in one probe
- Dual-level LCD
- Automatic calibration
- Operated by battery or 12 VDC
- °C and °F temperature scales
With features such as a built-in beaker holder, beaker-top electrode holder and rugged, 2-in-1 pH and temperature sensor, the HI 207 is designed to meet busy classroom environments. This instrument also features an extended pH range, dual-level LCD with icons for stability and buffer recognition, automatic pH calibration, and temperature display in either Celsius or Fahrenheit. In addition, all readings are automatically compensated for temperature variations. In the classroom, this compact unit reduces clutter and utilizes a minimal amount of space on the desktop. Switch to battery power and the instrument can be taken outside the classroom for field studies. When lab time is over, the meter is easily cleaned and can be placed out of the way—right away. (*) The temperature range is limited to 80 °C (176 °F) if using the HI 1291D probe. Order Information: HI 207-01 (115V) and HI 207-02 (230V) are supplied with HI 1291D pH electrode, HI 740035 pH electrode holder and plastic beaker, rubber O-ring, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, 12 VDC adapter, battery and instructions. - Specifications
- MSDS
- Accessories
- Downloads
| Range | pH | -2.00 to 16.00 pH | | Temperature | -5.0 to 105.0°C or 23.0 to 221.0°F | | Resolution | pH | 0.01 pH | | Temperature | 0.1°C or 0.1°F | | Accuracy | pH | ±0.02 pH | | Temperature | ±0.5 (up to 60°C); ±1°C (outside) ±1°F (up to 140°F); ±2°F (outside) | | Calibration | pH | Automatic 1 or 2 points with 2 sets of memorized buffers (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18) | Temperature Compensation | | Automatic | | pH Electrode | | HI 1291D with built-in temperature probe (included) | | Power Supply | | 12 VDC adapter (included) | | Battery Type / Life | | 9V / approximately 500 hours of continuous use | | Environment | | 0 to 50°C (32 to 122°F) 95% RH | | Dimensions | | 192 x 104 x 134 mm (7.5 x 4.1 x 5.3’’) | | Weight | | 420 g (14.8 oz.) | |
 | HI 2210 Basic PH Benchtop Meter | | |
| - Simple to operate
- Automatic temperature compensation
- Automatic calibration
- Calibration expiration reminder
- ORP range
HI 2210 is a benchtop pH and °C meter. This meter also features a reading stability indicator used during calibration and a measurement memory/memory recall function . pH measurements are compensated for the temperature effect manually or automatically with the HI 7662 temperature probe. These instruments are equipped with an easy-to-read LCD which shows both the primary reading and ºC. Order Information: HI 2210-01 (115V), HI 2210-02 (230V) and HI 2210-03 (AUS plug) are supplied with HI 1131B pH electrode, HI 7662 temperature probe, HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 7071S electrolyte solution (30 mL), HI 700661 cleaning solution sachet, 12 VDC adapter and instructions. - Specifications
- MSDS
- Accessories
- Downloads
| Range | pH | -2.00 to 16.00 pH | | Temperature | -20 to 120.0°C | | Resolution | pH | 0.01 pH | | Temperature | 0.1 °C | | Accuracy | pH | ±0.01 pH | | Temperature | ±0.4 °C (excluding probe error) | | pH Calibration | | automatic, 1 or 2 point with 5 memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01) | | Temperature Compensation | | automatic (with HI 7662 probe) or manual from -9.9 to 120 °C | | pH Electrode | | HI 1131B, glass-body, single junction, refillable, BNC connector, 1 m cable (included) | | Temperature Probe | | HI 7662 with 1 m (3.3') cable (included) | | Input Impedance | | 1012 Ohm | | Power Supply | | 12 VDC adapter (included) | | Environment | | 0 to 50°C (32 to 122°F); RH max 95% | | Dimensions | | 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”) | | Weight | | 1.3 kg (2.9 lbs.) | |
 | Hi 2212 PH Benchtop Meter With Three Point Calibration | | |
| - Up to three point pH calibration with five standard buffers or two custom
- GLP features
- Calibration expiration reminder
- Automatic Temperature Compensation
The HI 2212 is a pH and temperature benchtop meter. Calibration can be performed at up to three-points using five standard and two custom buffers. This instrument features manual or automatic temperature compensation with the HI 7662 temperature probe. GLP (Good Laboratory Practice) feature provides data consistency. A calibration reminder can be set to alert the user, that too much time has elapsed since the last pH calibration and a new one should be performed. Order Information: HI 2212-01 (115V) and HI 2212-02 (230V) are supplied with HI 1131B pH electrode, HI 7662 temperature probe, HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 7071S electrolyte solution (30 mL), HI 700661 cleaning solution sachet, 12 VDC adapter and instructions. - Specifications
- MSDS
- Accessories
- Downloads
| Range | pH | –2.00 to 16.00 pH | | Temperature | –20.0 to 120.0 ºC (-4.0 to 248.0ºF) | | Resolution | pH | 0.01 pH | | Temperature | 0.1 ºC | | Accuracy | pH | ±0.01 pH | | Temperature | ±0.2ºC (excluding probe error) | | pH Calibration | | Up to 3 point calibration, 5 standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01), and 2 custom buffers | | Temperature Compensation | | Manual or Automatic from -20 to 120ºC (-4.0 to 248.0ºF) | | pH Probe | | HI 1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included) | Temperature Probe | | HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included) | | Input Impedance | | 1012 ohm | | Power Supply | | 12 VDC adapter (included) | | Environment | | 0 to 50°C (32 to 122°F); RH max 95% | | Dimensions | | 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”) | | Weight | | 1.3 kg (2.9 lbs.) | |
|
 Product Showroom View all our products / services as a slide show. play now

|